CDA RC 9000 Users operating instructions Instrucciones de operaciones Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
43
Fig. 56
Fig. 57
Ring opening
Regulation of air supply to oven and grill burners
Using a screwdriver, slacken the screw securing the air flow regulation collar (fig. 56
and 57) and rotate the collar clockwise or anti-clockwise to increase or reduce the
air aperture in accordance with gas type and the indications in the “
TABLE FOR
THE CHOICE OF THE INJECTORS
”.
Light the burner and check the flame.