15
LPG to Natural Gas
Conversion
This hob can be converted from
propane operation at a nominal
inlet pressure of 37mbar or butane
operation at a nominal inlet pressure
of 28/30mbar to natural gas at 20mbar.
This conversion must only be carried
out by a competent person (i.e. a Gas
Safe registered fitter).
Required:
•7mmAFnutspinner
•Replacementinjectors
•NGidentityplate
Burner Size LPG Injector Natural Gas Injector
Auxiliary 49 72
Semi-Rapid 67 97
Rapid 86 115