- 4.1 Blower does not work properly.
- 4.2 Frequency inverter does not work properly.
5. Five pulses of light on red LED. D21 (fig 47)
Effect: The oven operates, but ignition is abrupt. The blower does not reach the minimum ignition
speed.
Possible causes:
- 5.1 Blower does not work properly.
5.2 Frequency inverter does not work properly.
6. Continuous light in red LED D21. (fig 47)
Effect: The oven does not ignite.
Possible causes:
- 6.1 Faulty ignition control, or broken internal ignition control fuse.
7. All LEDs off. D21 (fig 47)
Possible causes:
7.1 Check fuse.
7.2 Faulty inverter.
fig 46
Red LED
D21