11 PARAMETERS AND ADJUSTMENTS
The pressure values in ( mbar) are approximate. These are taken with an input pressure of 29 mbar Butane , 37 mbar Propane and 20 mbar Natural Gas
Burner ON
(V max)
Burner OFF
MODEL V ignition S1 V maximum S2
Ø Air washer Gas valve GV1-GV2 P out (mbar) P out (mbar)
HCG 6/11 B.P. Ve=1400 rpm V=4500 rpm Ø14: T-085013 T-085010
0:0,5
-0,8:-0,4
HCG 6/11 Prop. USA-60 Hz " V=5500 rpm " T-085016
HCG 6/11 B.P. Australia " " " T-085010
HCG 6/11 G.N. Ve=2000 rpm V=5000 rpm " T-085011
HCG 6/11 G.N. USA-60 Hz " V=5500 rpm " T-085017
HCG 6/11 G.N. Australia " " " T-085011
HCG 10/11 B.P. Ve=2000 rpm V=4000 rpm Ø18: T-115082 T-115097
0,3:1,1
-0,8:-0´3
HCG 10/11 Prop. USA-60 Hz " V=5000 rpm " T-115100
HCG 10/11 B.P. Australia " " " T-115097
HCG 10/11 G.N. Ve=2500 rpm V=4500 rpm Ø20: T-115083 T-115098
1,3:3
-0,9:0,1
HCG 10/11 G.N. USA-60 Hz " " " T-115101
HCG 10/11 G.N. Australia " " " T-115098
HCG 10/21 B.P. Ve=2000 rpm V=5500 rpm Ø18: T-115082 T-115097
0,5:1,8
-0,9:-0,3
HCG 10/21 Prop. USA-60 Hz " V=6000 rpm " T-115100
HCG 10/21 B.P. Australia " " " T-115097
HCG 10/21 G.N. Ve=2500 rpm V=6000 rpm Ø20: T-115083 T-115098
2:4
-0,8:0
HCG 10/21 G.N. USA-60 Hz " " " T-115101
HCG 10/21 G.N. Australia " " " T-115098