CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following opera-
tions:
Unscrew the screw A of the terminal board at the bottom of the hob (fig. 6.1).
Unlock the 2 clips B and open the cover C.
Unscrew the screw D and open completely the cable clamp E (fig. 6.3).
Position the U bolts F onto terminal board G (fig. 6.3) according to the diagram in fig. 6.2.
Connect the phase and earth wires to terminal board G according to the diagram in
fig. 6.2 and 6.3.
Strain the feeder cable and block it with cable clamp E (by screwing screw D).
Close the cover C of the terminal board G and block it with the screw A.
FEEDER CABLE SECTION
“Type H05VV-F or H05V2V2-F or H05RR-F”
Connection with wall box connection
220-240 V
~ 3 x 2,5 mm
2
(**)
(**) Connection with wall box connection.
Diversity factor applied
A diversity factor may be applied to the total loading of the appliance only by a suit-
ably qualified person.
1
2
3
5
4
N
E
L
F
D
C
G
E
Fig. 6.3