CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following opera-
tions:
PE
1
2
3
4
5
N (L2)L1
220-240 V
PE
1
2
3
4
5
380-415 V 2N
N
L1 L2
A
B
C
B
Fig. 6.4
Fig. 6.5
Unscrew the screw A of the terminal board at the bottom of the hob (fig. 6.4).
Unlock the 2 clips B and open the cover C.
Unscrew the screw D and open completely the cable clamp E (figs. 6.6 - 6.7).
Position the U bolts F onto terminal board G (figs. 6.6 - 6.7) according to the dia-
grams in fig. 6.5.
Connect the phase and earth wires to terminal board G according to the diagrams in
fig. 6.5.
Strain the feeder cable and block it with cable clamp E (by screwing screw D).
Close the cover C of the terminal board G and block it with the screw A.
FEEDER CABLE SECTION
“Type H05VV-F or H05V2V2-F or H05RR-F”
Connection with wall box connection
220-240 V
~ 3 x 2.5 mm
2
(**)
380-415 V 2N
~ 4 x 2.5 mm
2
(**)
(**) Connection with wall box connection.
Diversity factor applied
– A diversity factor may be applied to
the total loading of the appliance only
by a suitably qualified person.