CDA RC 9020 Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
41
Adjusting of the minimum of the top burners
Considering that in the minimum position the flame must have a length of about 4 mm
and must remain lit even with a quick turn from the maximum position to that of mini-
mum.
The flame adjustment is done in the following way:
– Turn on the burner
– Tum the tap to the MINIMUM position
– Take off the knob
– With a small flat screwdriver turn the screw inside the tap rod to the correct regula-
tion (fig. 39).
Normally for LPG, tighten up the regulation screw.
Fig. 39
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 47 48

Comentarios a estos manuales

Sin comentarios