CDA HCG 730 Users operating instructions El manual del propietario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 208
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
Convention Power indicator
pattern
Condition
CAUTION: When correcting a power supply unit mismatch,
replace only the power supply unit with the flashing indicator.
Swapping the opposite power supply unit to make a matched
pair can result in an error condition and unexpected system
shutdown. To change from a High Output configuration to a
Low Output configuration or vice versa, you must power
down the system.
CAUTION: AC power supplies support both 220 V and 110 V
input voltages with the exception of Titanium power supplies,
which support only 220 V. When two identical power supplies
receive different input voltages, they can output different
wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of the
same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not
supported and triggers a mismatch.
E Not lit Power is not connected.
Figure 15. DC power supply unit status indicator
1. DC power supply unit status indicator